CEHCO

Just another WordPress site

DEMO – SCR / DIODE TESTER

Enclosed are 9 pages of Demo- information for the Diode/SCR Tester T-101R.

Page 1: Operating Instructions: This is permanently pasted on the inside cover of the T-101R Tester.
Page 2: The front panel of the Main Unit. The tester is supplied with the Main Unit, Test leads, and a Compression Block.
Page 3: How to perform a SCR Leakage Test using a hockey puck SCR.
Page 4: Closer view of the Compression Block.
Page 5: How to perform a Diode Leakage Test, using hockey puck Diode.
Page 6: How to perform a Diode Leakage Test, using Axial Lead Diode.
Page 7: How to perform a Diode Leakage Test, using flex lead/threaded stud Diode.
Page 8: How to perform a SCR Gating Test, using flex lead/threaded stud Diode.
Page 9: How to perform a Diode Conduction Test, using flex lead/threaded stud Diode.

This tester has been used in the industry for over 20 years. The above test is very helpful in determining if a SCR or a Diode is defective or have marginal parameters.

DANGER-HIGH VOLTAGES ARE PRODUCED BY THIS
TESTER READ INSTRUCTIONS BEFORE USING

OPERATING INSTRUCTIONS

  1. INSERT LINE PLUG INTO A STANDARD 3 PRONG 120 VOLT A.C. RECEPTACLE.
  2. CHECK TO SEE THAT BOTH THE VOLTAGE CONTROLS, IN THE LEAKAGE SECTION AND GATING SECTION, ARE TURNED TO ZERO.

diode-tester-01

Diode/SCR Tester
T-101R

diode-tester-01

SCR Leakage Test – Leakage Section
Test Steps A1 to A9

diode-tester-02

Test Step A1

diode-tester-03

Diode Leakage Test – Leakage Section
Test Steps B1 to B5

diode-tester-04

Diode Leakage Test – Leakage Section
Test Steps B1 to B5

diode-tester-05

Diode Leakage Test – Leakage Section
Test Steps B1 to B5

diode-tester-06

SCR Gating – Gating Section
Test Steps C1 to C5

diode-tester-071

Diode Conduction – Gating Section
Test Steps D1 to D4

diode-tester-08

Print Friendly